(28115) 21, Yangcheong-3gil, Ochang-eup, Cheongwon-gu, Chungbuk, Korea
Tel : 043-711-8875 Fax : 043-711-8804
PREPARED AND CHECKED BY
AUTHORIZED BY
FOR FITI
FOR FITI
SEONG
KEUN JANG
JE
GOO JUN
QUALITY MANAGER
PRESIDENT
Report Verification No.: YNJH-MKAH-SUHE
(You can see the authenticity of your test report through the above "Report Verification No." at FITI homepage.)
The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
TEST REPORT
APPLICANT :
REPORT NO. :
M270-18-07908
SAMPLE RECEIVED DATE :
2018-06-29
TEST STARTED DATE :
2018-06-29
REPORT ISSUED DATE :
2018-07-09
PAGE :
1 OF 2
HANSE CORPORATION
DESCRIPTION :
ONE(1) PIECE OF SUBMITTED CUTTING SAID TO BE SHEET.
========================================================================================
==============
ITEM : GTF 0125
=======================================================
=================================
==============
TEST CONDUCTED :
AS REQUESTED BY THE APPLICANT, FOR DETAILS PLEASE SEE ATTACHED PAGE.
========================================================================================
==============
(28115) 21, Yangcheong-3gil, Ochang-eup, Cheongwon-gu, Chungbuk, Korea
Tel : 043-711-8875 Fax : 043-711-8804
REPORT NO.
:
M270-18-07908
PAGE :
2 OF 2
The test results contained in this report are limited to results on the sample(s) that is provided by client and are not necessarily indicative or representative
of the qualities of the lot from which the sample(s) was taken or of all products. Results contained in this report are not based on the quality certification
of sample by the FITI quality certification program unless specifically requested by the client. Further use of the results of this report is prohibited unless
allowed under a separate agreement set forth in an official document that is established between the client identified on this letter and the FITI.
This test report is irrelevant to KOLAS accreditation.
01.
COEFFICIENT OF RETROREFLECTION ( ISO 20471 : 2013 ) : cd/lx·
#1
SPECIMEN
OBSERVATION
ANGLE
ENTRANCE ANGLE COEFFICIENT OF RETROREFLECTION
93.3
20°
31.7
30°
11.6
12'
40°
6.6
85.2
20°
29.6
30°
10.7
20'
40°
6.0
25.1
20°
13.2
30°
4.6
40°
1.9
7.2
20°
6.7
30°
2.8
ε=0°
1°30'
40°
0.9
NOTE) TEST WAS CONDUCTED ONLY ε=0°DIRECTION BY THE CLIENT'S REQUEST.
THE TEST WAS CONDUCTED AFTER REMOVING THE RELEASE PAPER.
** End of The Report **
SAMPLE :